The MA20B torque transducers are used to measure static and dynamic torque in a non-turning mode.
— operating on the strain gauge principle;
— measuring of static and dynamic (rapidly changing) torque with correct polarity in a non-turning mode;
— MS-Windows compatible software in the scope of supply;
— flange-square mounting;
— direct PC connection via COM-, USB-, Ethernet- ports.
± 5 Nm; ± 10 Nm; ± 12 Nm; ± 15 Nm; ± 20 Nm± 30 Nm; ± 40 Nm; ± 50 Nm; ± 30 Nm;
± 60 Nm; ± 80 Nm; ± 100 Nm; ± 120 Nm; ± 150 Nm; ± 200 Nm; ± 300 Nm; ± 400 Nm; ± 500 Nm;
± 600 Nm; ± 800 Nm; ± 1 kNm
0.1
Nominal temperature range0… +60 °C
Nominal supply voltage12… 30 V (DC)
Power consumption<5 W
InterfaceUSB2.0; USB-VCOM (Virtual COM-port; USB-CDC); RS485; RS232; CAN; Ethernet
Sample rate5.0 kSample
Digitizing16 bit
Nominal output signal or current± 5 V; ± 10 V; 4 … 20 mA
Measurement frequency range0 … 1 000 Hz (- 1.5 dB)
Frequency output10 kHz ± 5 kHz; 60 kHz ± 30 kHz
TILKOM can develop special accessories and software according to our customers' technical requirements.